Functional Safety Manager, Industrial Battery Management
Listed on Renesas Electronics’s official careers site. Posted October 28, 2026. Check that it is still open and apply there.
Apply on Renesas Electronics’s careers site →Job description
Responsibilities
Single point of contact on functional safety for lead customers and their certification bodies; present and defend the safety concept, safety manual and FMEDA. Derive the IC-level safety requirements with customer system safety teams (safety functions, target SIL, demand mode, proof-test interval, diagnostic coverage); agree a DIA or equivalent. Support customer UL 1973 / UL 9540 / IEC 62619 listings where BMS safety functions are in scope; close assessor findings.
Represent the company at standards and industry forums.
Own the safety decisions for the product line
target SIL per safety function, safety concept, architecture trade-offs. Define and run the functional safety management system (IEC 61508-1 clause 6): safety plan, roles and competence, independence, tailoring, safety case per product. Structure the safety requirements work (derivation, allocation, traceability, verification) and drive the lifecycle from concept through IC design, silicon validation, firmware and release: hardware safety architecture, FMEDA and pin FMEA, DFA, FTA, diagnostic coverage, PFH and SFF / HFT (Route 1H / 2H), proven-in-use where applicable.
Own the safety manual and evidence package for compliant items; keep what design and firmware build consistent with the standard and the safety concept.
Set best practice for design and verification
safety design reviews, fault-injection and diagnostic verification, tool qualification, change and impact management for derivatives and die revisions. Plan and run third-party assessment and certification (TUV, exida, UL) and internal safety audits; close nonconformities.
Cover adjacent requirements
IEC 60730-1 Annex H, IEC 63056, IEC 62619 clause 8, EU Batteries Regulation 2023/1542, JIS C 8715-2; align with product security on IEC 62443-4-1 / 4-2 so safety and security share one process. Build safety competence across the IC design organization; define and hire the functional safety team as the product line grows. Working Pattern This role supports customers and internal teams across North America and Asia. As a result, early morning or evening meetings may occasionally be required to accommodate different time zones.
In return, we offer a high degree of flexibility in both working hours and location. We value outcomes over time spent and measure success based on results and impact rather than hours worked. *The full details regarding your position scope as well as any future potential changes in work location and job scope will be provided during the interview process.
Qualifications
MUST 10+ years in electronics or semiconductor development, including 5+ years leading functional safety on products certified to IEC 61508 or ISO 26262, with demonstrated ability to work to IEC 61508 (SIL 2 or higher), the standard this role delivers against. Must have taken an IC, module or controller through third-party assessment. Hands-on command of IEC 61508-1, -2 and -3: hardware architectural constraints, FMEDA, diagnostic coverage, PFH / PFD, safety manuals for compliant items, software safety lifecycle.
Working knowledge of at least one of: UL 1973, UL 9540, IEC 62619, IEC 60730-1 Annex H, IEC 62061 / ISO 13849, UL 991 / UL 1998.
Battery system fluency
cell monitoring, balancing, contactor control, isolation, thermal management, state estimation, and the failure modes that matter (overcharge, over-discharge, over-temperature, short circuit, thermal propagation). Enough mixed-signal and digital IC design background to review safety architectures and diagnostics with designers as a peer. Track record of making and defending safety decisions with engineering and business leadership, setting up requirements processes from scratch, and running customer engagements and assessor audits.
Fluent written and spoken English and Japanese. Degree in electrical engineering or a related field. Preferred TUV FS Engineer / Expert, exida CFSE / CFSP, or UL functional safety certification. IEC 61508 delivery in stationary storage, industrial automation or process instrumentation; ISO 26262 alongside it helps with customers taking the ASIL C route under UL 9540. IEC 62443-4-1 / 4-2 exposure (safety and security share one lifecycle here); ISO/SAE 21434 acceptable as an alternative.
Familiarity with OCP ORv3 BBU specifications or data-center power architecture.
More jobs at Renesas Electronics
ARM CPU Subsystem Design Leader
Kodaira, Japan
Application Engineer
Kodaira, Japan
CPU Subsystem Engineering Manager
Kodaira, Japan
Similar jobs at other companies
Sr Key Accounts Manager (Industrial/Semi/Battery)
Thermo Fisher Scientific · Giheung, Korea, Republic of
Functional Safety Engineer
ABB · Brno, Jihomoravský kraj, Czechia
Functional Safety Specialist
ABB · Ostrava, Moravskoslezský kraj, Czechia
Machine Functional Safety Specialist
SGS · Senai, Johor, Malaysia